1997 to 2026
Experience & projects





CCS Network (ME) Ltd continues a coating business that began in 1997. A later company, then called CCS Network Ltd, was formed to take product distribution globally and to represent the application partner network. Today’s legal entity, as registered at Companies House, is CCS Network (ME) Ltd. Our own applications run from 1997 to date across the United Kingdom, the Republic of Ireland and the Netherlands. We have trained application teams and overseen applications throughout Europe, the Middle East and Africa.
- Transmission and distribution insulators up to 400 kV.
- Generating stations, including coastal and industrially polluted sites.
- Environments with salt, coal dust, cement, iron ore and petrochemical pollution.
- Insulators and bushings; substation metalwork, including gantries, structures and cabinets; and air-core reactor coils.
- 1997
An HVIC application company
Commercial Coating Systems Ltd was founded by Chris Cork and Barry Field as an RTV silicone HVIC application company, for pollution management on high-voltage systems. The first jobs were carried out at Dungeness, Kingsnorth and Heysham.
Case study (coming soon) - 2003 to 2019
Master distributor for Dow Corning
In 2003 CCS became the master distributor for Dow Corning RTV silicone HVIC, and remained so until 2019.
Case study (coming soon) - 2005
Sellindge
The UK reference list records capacitor-coil work at Sellindge.
Case study (coming soon) - 23 June 2010
Hinkley Point 400 kV
Inspection of RTV silicone HVIC, then about seven to eleven years in service, still adherent and suitable for overcoating.
Case study (coming soon) - May 2013
Fiddlers Ferry
The UK reference list records work including Reactor 2.
Case study (coming soon) - 2019
Partnership with CSL Silicones
A distribution agreement was signed on 10 July 2019. CSL and CCS announced a partnership for Si-COAT 570 on 16 and 18 July 2019. The original announcement described an EMEA territory; that description has since been updated.
Case study (coming soon) - 1997 to present
Documented UK programme
With nearly 30 years of HV insulator coating experience, the CCS UK reference list records RTV silicone HVIC application work including circuits at Dungeness, Tod Point, Shoreham, Littlebrook, Aberthaw, Grendon, Pembroke, Fawley, Capenhurst, Blyth, Ratcliffe, Margam, Chickerell, Grain, Cellarhead, Killingholme, West Burton, Eggborough, Bangor, Cottam, Drax, Enderby, Tremorfa, Wylfa, Keadby and many more sites.
Case study (coming soon) - 1–2 October 2020
Lincs OFTO, adjacent to Walpole
Remove existing RTV silicone HVIC, clean and re-apply to a shunt reactor, with patch repairs where required. Recorded for Transmission Capital.
Case study (coming soon) - 26–27 October 2020
Heysham Substation
Remove existing RTV silicone HVIC, clean and re-apply to a reactor coil. Recorded for Transmission Capital Services.
Case study - October 2020
Transmission Investment OFTO, B24
Lower coil coating works.
Case study (coming soon) - 30 August–16 September 2023
Choats Road, Barking
Clean, remove existing RTV silicone HVIC if necessary, and re-apply to two reactor coils. UK Power Networks substation; client Hitachi Energy.
Case study (coming soon) - September 2023
Transmission Investment OFTO, B24
Upper-middle coil coating works.
Case study (coming soon) - October 2023
Tilbury 400 kV
National Grid. Degrease, clean and polish. Not a coating application.
Case study (coming soon) - 11–13 March 2024
Sundon Substation
National Grid. Remove old RTV silicone, clean and coat one reactor coil with Si-COAT 570.
Case study (coming soon) - 3 April 2025
Sellindge 400 kV converter station
Inspection of twelve factory-pre-coated reactor coils. Not an overcoat.
Case study (coming soon) - March 2026
Nechells 275/132 kV
National Grid. Apply Si-COAT 570.
Case study (coming soon) - May 2026
Pembroke 400 kV / Swansea North 2
National Grid. Overcoat.
Case study (coming soon)
Case studies
| Site | Customer | Problem | Year | |
|---|---|---|---|---|
| Aberthaw 275 kV, Upper Boat 2 | National Grid | Coal dust, salt and cement | 2009 | |
| Blyth 275 kV, Fourstones | National Grid | Saline pollution | 2010 | |
| Blyth 275 kV, Stella West 2 | National Grid | Saline pollution | 2010 | |
| Gortawee 110 kV, Quinn cement works | ESB | Cement dust | 2010 | |
| Fiddlers Ferry 275 kV, Rainhill 1 | National Grid | Coal dust | 2010 | |
| Hinkley Point 275 kV cable sealing ends | National Grid | Saline pollution | 2010 | |
| Hinkley Point 275 kV, SGT6 | National Grid | Hybrid application trial | Not stated | |
| Littlebrook 400 kV | National Grid | Industrial and road pollution | 2008 | |
| Sellindge, Pole 3 converter | National Grid | Cascading rain on an inclined bushing | 2010 | |
| Shoreham 132 kV switchyard | Scottish Power | Sea spray | 2007 | |
| Heysham SGT2 | National Grid | Salt fog | 2010 | |
| Ratcliffe, generator transformer 3 | Not named beyond the site | Coal dust | 2020 | |
| The Grange, Port Talbot | Not named beyond the site | Industrial pollution and iron ore dust | 2020 | |
| Margam, Baglan Bay L13 | Not named beyond the site | Industrial pollution | 2020 | |
| Dungeness 400 kV substation | Not named beyond the site | Corrosion from water and salt | 2020 | |
| Frodsham | Not stated | Wall bushings before coating, during application, and after coating | Not stated | |
| Swansea North | Not stated | Wall bushings and posts before and after coating | Not stated | |
| Tod Point | Not stated | Current transformers and disconnect posts, coated | Not stated | |
| Rocamora | Not stated | Post insulators during preparation and coating | Not stated |
Reactor-coil jobs are listed in full on the Reactor coils page.